Skip to content Skip to navigation menu
Vickers by Danfoss02-329181

02-329181

Vickers D08 Solenoid Valve
Item #101978005
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329181
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Valve Type Standard-Duty
Coil Type Code U
Compatible Fluids Petroleum Oil
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Pressure Code None
Surge Suppressor/Damper None
Electrical Options Code None
Housing Code None
Function 3-Position Spring Centered
Manual Override Option Code None
Spool Control Modification Code None
Pilot Valve Type CETOP 3, Standard Performance
Electrical Connector Code None
Solenoid Energization Code None
Pressure Port Check Valve Pressure N/A
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Solenoid Double
Gauge Ports Code None
Pressure Port Check Valve Code None
Port Restrictor Plug Code None
Mechanical Options Code None
Spool Code 6
Operation Pilot Operated
Indicator Lights No
Coil Type ISO 4400 (Din 43650) Connector
Electrical Options None
Port Restrictor Plugs None
Coil Rating Code B
Temperature Range [Min] -40 °F
Gauge Port SAE-4
Leakage Standard Performance
Actuator Type Solenoid
EN Code None
Response Type Standard Response
Manual Override Plain Override
Response Type Code None
Port T Pressure Rating 5000 psi
Actuation Identification Solenoid A, Solenoid B
AC/DC AC
Model No. DG5V-8-S-6C-T-M-U-B-10
Performance Standard Performance
Mounting Subplate/Manifold Mount
Crossover P Blocked, A or B to T
Overrides Plain Override Solenoid Ends
Rated Flow [Max] 175 gal/min
Solenoid Indicator Lights Code None
Pilot/Drain External Pilot/Internal Drain
Electrical Connection No Connector
Surge Suppressor/Damper Code None
Tank Port Rating 5000
Reducer Module Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
NFPA Size D08
Seal Material Buna-N
Fluid Cleanliness 19/17/14 micron
Reducer Module No
No. of Stages Two Stage
Design No. 10
Center Position P Blocked, A & B to T
Spool Spring Arrangement Code C
Temperature Range [Max] 230 °F
Body Material Ductile Iron
Pilot Valve Type Code S
Mechanical Options None
Pilot Drain Code T
Weight 35.0 LB