- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Solenoid Energization Code | None |
| Spool Spring Arrangement Code | C |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Manual Override | Plain Override |
| Mounting | Subplate/Manifold Mount |
| Port T Pressure Rating | 5000 psi |
| NFPA Size | D08 |
| Port Restrictor Plug Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Function | 3-Position Spring Centered |
| Spool Code | 6 |
| Manual Override Option Code | None |
| Reducer Module Code | None |
| Body Material | Ductile Iron |
| Model No. | DG5V-8-S-6C-T-M-FW-B-10 |
| Surge Suppressor/Damper Code | None |
| Electrical Options | None |
| Compatible Fluids | Petroleum Oil |
| Pressure Port Check Valve Pressure | N/A |
| Crossover | P Blocked, A or B to T |
| Leakage | Standard Performance |
| Indicator Lights | No |
| AC/DC | AC |
| Solenoid Indicator Lights Code | None |
| Coil Rating Code | B |
| Valve Type | Standard-Duty |
| Pilot/Drain | External Pilot/Internal Drain |
| Surge Suppressor/Damper | None |
| Mechanical Options Code | None |
| Mechanical Options | None |
| Design No. | 10 |
| Seal Material | Buna-N |
| Pressure Port Check Valve Code | None |
| Spool Control Modification Code | None |
| Center Position | P Blocked, A & B to T |
| Electrical Connector Code | None |
| Spool Indicator Switch Code | None |
| Actuator Type | Solenoid |
| Gauge Port | SAE-4 |
| Reducer Module | No |
| Response Type | Standard Response |
| Pilot Drain Code | T |
| Electrical Connection | No Connector |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Pilot Pressure Code | None |
| Temperature Range [Min] | -40 °F |
| Fluid Cleanliness | 19/17/14 micron |
| Pressure [Max] | 5000 psi |
| Solenoid | Double |
| Performance | Standard Performance |
| Tank Port Rating | 5000 |
| Port Restrictor Plugs | None |
| No. of Stages | Two Stage |
| Gauge Ports Code | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| EN Code | None |
| Overrides | Plain Override Solenoid Ends |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Coil Type Code | F |
| Electrical Options Code | None |
| Operation | Pilot Operated |
| Rated Flow [Max] | 175 gal/min |
| Temperature Range [Max] | 230 °F |
| Housing Code | W |
| Pilot Valve Type Code | S |
| Response Type Code | None |
| Weight | 35.0 LB |