Vickers by Danfoss02-329170

02-329170

Vickers D08 Solenoid Valve
Item #101975667
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329170
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Should not be used in other areas such as spindles or gearbox shafting without approval by Torrington Engineering Department.
NFPA Size D08
Spool Spring Arrangement Code C
Center Position P Blocked, A & B to T
Coil Rating Code D
Voltage & Frequency 220/240 VAC - 50/60 Hz
Function 3-Position Spring Centered
Electrical Connection No Connector
Mechanical Options Code None
Manual Override Option Code None
Port T Pressure Rating 5000 psi
Solenoid Indicator Lights Code None
Port Restrictor Plugs None
Pilot Pressure Code None
Housing Code None
Pressure [Max] 5000 psi
Coil Type DIN 43650
Electrical Options None
Port Restrictor Plug Code None
Overrides Plain Override Solenoid Ends
Solenoid Energization Code None
AC/DC AC
Surge Suppressor/Damper Code None
Pilot/Drain External Pilot/Internal Drain
Manual Override Plain Override
Electrical Options Code None
Pilot Valve Type CETOP 3, Standard Performance
Spool Control Modification Code None
Response Type Standard Response
Pilot Drain Code None
Pressure Port Check Valve Pressure N/A
Coil Type Code U
Design No. 10
Model No. DG5V-8-S-6C-M-U-D-10
Operation Pilot Operated
Gauge Port SAE-4
Surge Suppressor/Damper None
Electrical Connector Code None
Spool Code 6
Mechanical Options None
Spool Indicator Switch Code None
Solenoid Double
Rated Flow [Max] 185 gal/min
Response Type Code None
Seal Material Buna-N
Actuator Type Solenoid
Crossover P Blocked, A or B to T
Reducer Module N/A
Indicator Lights No
EN Code None
Tank Port Rating 5000
Valve Type Standard-Duty
Pilot Valve Type Code S
Reducer Module Code None
Gauge Ports Code None
Pressure Port Check Valve Code None
Weight 35.0 LB