Vickers D08 Solenoid Valve
Item #101978263
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-325884
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
NFPA Size D08
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Performance Standard Performance
Indicator Lights No
Spool Control Modification Code None
Coil Type Code F
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Body Material Ductile Iron
Mechanical Options None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Electrical Connector Code None
Reducer Module No
EN Code None
Solenoid Double
Port T Pressure Rating 5000 psi
Solenoid Indicator Lights Code None
Pilot Pressure Code None
No. of Stages Two Stage
Housing Code W
Tank Port Rating 5000
Pilot Valve Type Code S
Pilot/Drain External Pilot/Internal Drain
Gauge Port SAE-4
Actuation Identification Solenoid A, Solenoid B
Pressure [Max] 5000 psi
Fluid Cleanliness 20/18/15 micron
Model No. DG5V-8-S-0C-S-M-FW-B-10
Rated Flow [Max] 175 gal/min
Compatible Fluids Petroleum Oil
Valve Type Standard-Duty
Function 3-Position Spring Centered
Electrical Options None
Pilot Drain Code None
Surge Suppressor/Damper None
Mechanical Options Code None
Electrical Connection No Connector
Port Restrictor Plugs None
Response Type Code None
Manual Override Option Code None
Solenoid Energization Code None
Actuator Type Solenoid
Temperature Range [Max] 230 °F
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Spring Arrangement Code C
Spool Code 0
Manual Override Plain Override
Leakage Standard Performance
Center Position All Ports Open
Reducer Module Code None
Port Restrictor Plug Code None
Pilot Valve Type CETOP 3, Standard Performance
Coil Rating Code B
Crossover All Ports Open
Operation Pilot Operated
Mounting Subplate/Manifold Mount
Seal Material Buna-N
Temperature Range [Min] -40 °F
Gauge Ports Code None
Pressure Port Check Valve Pressure 75 psi
AC/DC AC
Pressure Port Check Valve Code S
Spool Indicator Switch Code None
Response Type Standard Response
Design No. 10
Electrical Options Code None
Surge Suppressor/Damper Code None
Overrides Plain Override Solenoid Ends
Weight 35.0 LB