Vickers D08 Solenoid Valve
Item #101978016
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-325865
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Fluid Cleanliness 19/17/14 micron
Pilot/Drain External Pilot/Internal Drain
Solenoid Indicator Lights Code None
Electrical Options Code None
Port Restrictor Plug Code None
Mounting Subplate/Manifold Mount
Gauge Port SAE-4
Actuator Type Solenoid
Center Position All Ports Blocked
Housing Code None
NFPA Size D08
Surge Suppressor/Damper Code None
Manual Override Option Code None
Solenoid Single
Mechanical Options Code None
Response Type Code None
Crossover All Ports Blocked
Actuation Identification Solenoid B
Body Material Gray Iron
Reducer Module Code None
Overrides Plain Override Solenoid Ends
Pressure [Max] 5000 psi
Seal Material Buna-N
Operation Pilot Operated
Pilot Valve Type Code S
Electrical Connector Code None
No. of Stages Two Stage
Solenoid Energization Code None
Electrical Connection No Connector
Pilot Valve Type CETOP 3, Standard Performance
Pressure Port Check Valve Code None
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper None
Leakage Standard Performance
Rated Flow [Max] 175 gal/min
Gauge Ports Code None
Spool Code 2
AC/DC AC
Coil Type ISO 4400 (Din 43650) Connector
Electrical Options None
Reducer Module No
Pilot Pressure Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Valve Type Standard-Duty
Pilot Drain Code None
Indicator Lights No
Spool Control Modification Code None
Spool Center Condition B Port End
Compatible Fluids Petroleum Oil
Mechanical Options None
Manual Override Plain Override
Performance Standard Performance
Port T Pressure Rating 5000 psi
Model No. DG5V-8-S-2A-M-U-B-10
Function 2-Position Spring Offset
Response Type Standard Response
Coil Type Code U
Port Restrictor Plugs None
EN Code None
Spool Indicator Switch Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Design No. 10
Coil Rating Code B
Tank Port Rating 5000
Spool Spring Arrangement Code A
Weight 35.0 LB