Vickers D03 Solenoid Valve

02-323453

Vickers D03 Solenoid Valve
Item #102085833
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Solenoid Code H
Design No. 60
Manual Override Plain Override
Manual Override Option Code None
Spool Code 2
Compatible Fluids Petroleum Oil
Spool Spring Arrangement Code A
Valve Type High-Performance
Performance High Performance
Electrical Connection Wired Terminal Block
Surge Suppressor/Damper Encapsulated Transzorb
Leakage Standard Performance
Spool Shift Timing N/A
Rated Flow [Max] 20 gal/min
Mounting Subplate/Manifold Mount
Reducer Module No
Tank Port Rating 3046
Solenoid Indicator Lights Code L
Housing Code W
Electrical Options None
No. of Stages Single Stage
Response Type Standard Response
Function Code 2
Actuator Type Solenoid
Operation Solenoid Operated
Actuation Identification Solenoid B
Overrides No Overrides
Function 2-Position Spring Offset, End to End
Voltage & Frequency 24 VDC
Port T Pressure Rating 3000 psi
Pressure [Max] 5000 psi
Indicator Lights Yes
Pilot/Drain None
Watt Rating 30 W
Coil Rating Code H
Response Time 28 to 45 ms
Body Material Gray Iron
Pressure Port Check Valve Pressure N/A
Fluid Cleanliness 19/17/14 micron
NFPA Size D03
Pilot Valve Type N/A
Cycle Rate [Max] N/A
Temperature Range [Max] 158 °F
Electrical Connector Code T
Model No. DG4V-3-2A-M-FTWL-D7-H7-60
Center Position All Ports Blocked
Solenoid Single
AC/DC DC
Surge Suppressor/Damper Code D7
Mechanical Options None
Solenoid Energization Code None
Spool Indicator Switch Code None
Port T Code 7
EN Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plug Code None
Seal Material Buna-N
Crossover All Ports Blocked
Port Restrictor Plugs None
Coil Type Code F
Temperature Range [Min] -4 °F
Weight 5.0 LB