Vickers D10 Solenoid Valve
Item #101977728
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-321781
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Solenoid Energization Code None
Operation Pilot Operated
Crossover All Ports Blocked
Pilot Drain Code None
Overrides Plain Override Solenoid Ends
Housing Code None
Valve Type Standard-Duty
Pilot Pressure [Max] 3000 psi
Spool Code 2
Actuator Type Solenoid
NFPA Size D10
Tank Port Rating 3000
Manual Override Option Code None
Indicator Lights No
Coil Rating Code D
Pressure Port Check Valve Pressure N/A
Pilot Valve Type Code S
Electrical Connection No Connector
Design No. 10
Solenoid Indicator Lights Code None
AC/DC AC
Rated Flow [Max] 290 gal/min
Gauge Ports Code None
Electrical Connector Code None
Response Type Standard Response
Pressure [Max] 5000 psi
Reducer Module N/A
Coil Type DIN 43650
Pilot Pressure Code None
Voltage & Frequency 220/240 VAC - 50/60 Hz
Port T Pressure Rating 3000 psi
Center Position All Ports Blocked
Solenoid Double
Pilot Valve Type CETOP 3, Standard Performance
Spool Control Modification Code None
Surge Suppressor/Damper Code None
Coil Type Code U
Pilot/Drain External Pilot/Internal Drain
Spool Spring Arrangement Code C
Function 3-Position Spring Centered
Assembly Code None
Mechanical Options None
Port Restrictor Plug Code None
Pressure Port Check Valve Code None
Electrical Options Code None
Response Type Code None
Surge Suppressor/Damper None
Manual Override Plain Override
EN Code None
Gauge Port SAE-4
Electrical Options None
Port Restrictor Plugs None
Reducer Module Code None
Seal Material Buna-N
Model No. DG5V-10-S-2C-M-U-D-10
Weight 100.0 LB