02-157307

Vickers D03 Solenoid Valve
Item #102031007
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Pressure [Max] 5000 psi
Electrical Connector Code T
Solenoid Single
Indicator Lights Yes
Rated Flow [Max] 20 gal/min
Coil Rating Code B
Manual Override Option Code None
Actuator Type Solenoid
EN Code None
Port T Code 6
Overrides No Overrides
Temperature Range [Max] 158 °F
Spool Shift Timing N/A
Valve Type High-Performance
AC/DC AC
Solenoid Energization Code None
Function 2-Position Spring Offset, End To Center, Left Hand Build
Response Type Standard Response
Actuation Identification Solenoid A
Design No. 60
Cycle Rate [Max] N/A
Compatible Fluids Petroleum Oil
No. of Stages Single Stage
Temperature Range [Min] -4 °F
Leakage Standard Performance
Surge Suppressor/Damper Code None
NFPA Size D03
Housing Code W
Performance High Performance
Reducer Module No
Pilot/Drain None
Response Time 15 to 23 ms
Pilot Valve Type N/A
Port T Pressure Rating 3000 psi
Solenoid Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plugs None
Mechanical Options None
Surge Suppressor/Damper None
Crossover All Ports Open
Manual Override Plain Override
Fluid Cleanliness 19/17/14 micron
Mounting Subplate/Manifold Mount
Center Position All Ports Open
Port Restrictor Plug Code None
Seal Material Buna-N
Electrical Options None
Spool Indicator Switch Code None
Spool Spring Arrangement Code B
Spool Code 0
Operation Solenoid Operated
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Pressure N/A
Coil Type Code F
Solenoid Indicator Lights Code L
Model No. DG4V-3-0BL-M-FTWL-B6-60
Body Material Gray Iron
Function Code 0
Electrical Connection Wired Terminal Block
Tank Port Rating 3046
Weight 5.0 LB