Vickers D05 Solenoid Valve
Item #102031020
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-155813
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Steel housings must be used for operating pressures above 3,000 psi
Temperature Range [Min] 68 °F
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 24 VDC
Coil Rating Code H
Performance Standard Performance
Compatible Fluids Petroleum Oil
Spool Spring Arrangement Code N
Temperature Range [Max] 122 °F
Overrides No Overrides
Flow Direction Code 4
Function 3-Position Detented
Mechanical Options Code None
Response Type Standard Response
Pilot/Drain None
Response Time 60 ms
Spool Code 6
Watt Rating 30 W
Coil Type Code None
Center Position P Blocked, A & B to T
Pressure [Max] 7500 psi
Seal Material Buna-N
Electrical Options Code None
Mechanical Options None
Cycle Rate [Max] N/A
Actuator Type Solenoid
AC/DC DC
Port Restrictor Plugs None
Tank Port Rating 1000
Model No. DG4S4-016N-H-61
Rated Flow [Max] 24 gal/min
Pilot Valve Type N/A
Design No. 61
NFPA Size D05
Electrical Options None
Indicator Lights No
Valve Type Standard-Duty
Pressure Port Check Valve Pressure N/A
Electrical Connection Lead Wires w/o Terminal Box
Leakage Standard Performance
Operation Solenoid Operated
Manual Override Plain Override
Actuation Identification Solenoid A, Solenoid B
Reducer Module N/A
Body Material Gray Iron
Surge Suppressor/Damper None
Port T Pressure Rating 1000 psi
Coil Type Flying Leads
No. of Stages Single Stage
Solenoid Double
Mounting Subplate/Manifold Mount
Crossover P Blocked, A or B to T
Weight 10.0 LB