Skip to content Skip to navigation menu
Vickers by Danfoss02-148824

02-148824

Vickers D07 Solenoid Valve
Item #102037975
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-148824
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Housing Code W
Operation Solenoid Operated
Electrical Connector Code None
Pilot Valve Type N/A
Mechanical Options None
Coil Rating Code B
Assembly Code None
Tank Port Rating 1450
Design No. 60
Pressure Port Check Valve Pressure N/A
Coil Type Code F
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Pressure Port Check Valve Code None
AC/DC AC
Electrical Connection No Connector
Crossover All Ports Blocked
Response Type Standard Response
Surge Suppressor/Damper None
EN Code None
Pilot/Drain External Pilot/Internal Drain
NFPA Size D07
Valve Type Standard-Duty
Manual Override Plain Override
Electrical Options None
Port Restrictor Plug Code None
Seal Material Buna-N
Pilot Drain Code T
Center Position All Ports Blocked
Overrides Plain Override Solenoid Ends
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Type Code None
Indicator Lights No
Spool Control Modification Code None
Pressure [Max] 3000 psi
Mounting Screw Option Code N/A
Solenoid Double
Rated Flow [Max] 60 gal/min
Function 3-Position Detented
Manual Override Option Code None
Spool Code 2
Spool Spring Arrangement Code N
Model No. DG5S4-042N-T-M-FW-B5-60
Spool Indicator Switch Code None
Reducer Module N/A
Electrical Options Code None
Pilot Pressure Code None
Solenoid Energization Code None
Pilot Valve Tank Pressure Rating Code 5
Port Restrictor Plugs None
Port T Pressure Rating 1450 psi
Weight 15.0 LB