Vickers by Danfoss02-134240

02-134240

Vickers D07 Solenoid Valve
Item #102048609
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-134240
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
No. of Stages Two Stage
Reducer Module N/A
Coil Rating Code B
Manual Override Option Code None
AC/DC AC
Coil Type 1/2 in NPT Thread Wiring Housing
Indicator Lights No
Spool Spring Arrangement Code C
Pressure Port Check Valve Code None
Surge Suppressor/Damper None
Spool Indicator Switch Code None
Response Type Code None
Center Position P & B Blocked, A to T
Overrides Plain Override Solenoid Ends
Manual Override Plain Override
Housing Code W
Function 3-Position Spring Centered
Design No. 60
Compatible Fluids Petroleum Oil
Electrical Connection No Connector
Rated Flow [Max] 60 gal/min
Actuation Identification Solenoid A, Solenoid B
Pilot Valve Type N/A
Actuator Type Solenoid
Body Material Gray Iron
Electrical Connector Code None
Performance Standard Performance
Crossover All Ports Blocked, or P & B Blocked, A to T
Pressure [Max] 3000 psi
Pilot Drain Code None
Solenoid Indicator Lights Code None
Electrical Options Code None
Mounting Screw Option Code N/A
Response Type Standard Response
NFPA Size D07
Pilot/Drain External Drain
Port T Pressure Rating 1450 psi
Coil Type Code F
Spool Control Modification Code None
Fluid Cleanliness 19/17/14 micron
Operation Solenoid Operated
Leakage Standard Performance
Port Restrictor Plug Code None
Pressure Port Check Valve Pressure N/A
Model No. DG5S4-043C-M-FW-B5-60
Pilot Valve Tank Pressure Rating Code 5
Assembly Code None
Solenoid Double
Seal Material Buna-N
Port Restrictor Plugs None
EN Code None
Solenoid Energization Code None
Tank Port Rating 1450
Valve Type Standard-Duty
Mechanical Options None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mounting Subplate/Manifold Mount
Electrical Options None
Spool Code 3
Pilot Pressure Code None
Weight 15.0 LB