Vickers D05 Solenoid Valve
Item #101974086
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End to Center, Single End Function
Vickers by Danfoss02-126195
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End to Center, Single End Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Center Position P to A & B, T Blocked
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Pressure N/A
Coil Rating Code B
Solenoid Single
Rated Flow [Max] 25 gal/min
Design No. 60
Pilot/Drain None
Spool Code 7
Pressure [Max] 3600 psi
Indicator Lights No
Electrical Options None
Surge Suppressor/Damper None
Model No. DG4S4-017B-B-60-LH
Mechanical Options Single Solenoid Reverse Assembly
Mechanical Options Code LH
Function 2-Position Spring Centered, End to Center, Single End
NFPA Size D05
Tank Port Rating 1000
Pilot Valve Type N/A
Flow Direction Code 4
Operation Solenoid Operated
Overrides No Overrides
Coil Type Code None
Port T Pressure Rating 1000 psi
Port Restrictor Plugs None
Coil Type Flying Leads
Actuator Type Solenoid
AC/DC AC
Reducer Module N/A
Electrical Options Code None
Valve Type Standard-Duty
Response Type Standard Response
Spool Spring Arrangement Code B
Crossover P to A or B, T & A or B Blocked
Seal Material Buna-N
Electrical Connection KU W/ Deutsch Connector
Cycle Rate [Max] N/A
Weight 10.0 LB