Vickers D03 Solenoid Valve

02-110415

Vickers D03 Solenoid Valve
Item #101950106
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Multi-fluid capability without the need to change seals
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
Pilot/Drain None
Solenoid Double
Surge Suppressor/Damper None
EN Code None
Model No. DG4V-3-2N-M-FTWL-B6-60
Pressure Port Check Valve Pressure N/A
Body Material Gray Iron
Electrical Connector Code T
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Valve Type N/A
Tank Port Rating 3046
Fluid Cleanliness 19/17/14 micron
Seal Material Buna-N
Manual Override Plain Override
Function Code 2
Manual Override Option Code None
Operation Solenoid Operated
Solenoid Code B
Port Restrictor Plug Code None
Crossover All Ports Blocked
Compatible Fluids Petroleum Oil
Response Time 15 to 23 ms
Response Type Standard Response
Cycle Rate [Max] N/A
Electrical Connection Wired Terminal Block
Spool Indicator Switch Code None
Pressure [Max] 5000 psi
Solenoid Energization Code None
Port Restrictor Plugs None
NFPA Size D03
Performance Standard Performance
Rated Flow [Max] 20 gal/min
Mechanical Options None
Function 3-Position Detented
Coil Rating Code B
Overrides No Overrides
Indicator Lights Yes
Electrical Options None
Housing Code W
Actuator Type Solenoid
Spool Shift Timing N/A
Watt Rating 20 W
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Center Position All Ports Blocked
Spool Center Condition A Port and Double Offset sensing switch on B Port
Temperature Range [Min] -4 °F
Port T Pressure Rating 3000 psi
Solenoid Indicator Lights Code L
Port T Code 6
Actuation Identification Solenoid A, Solenoid B
Leakage Standard Performance
Design No. 60
AC/DC AC
Coil Type Code F
Reducer Module No
Valve Type High-Performance
Mounting Subplate/Manifold Mount
Spool Code 2
Surge Suppressor/Damper Code None
No. of Stages Single Stage
Temperature Range [Max] 158 °F
Spool Spring Arrangement Code N
Weight 5.0 LB