- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
AC/DC | AC |
Valve Type | Standard-Duty |
Overrides | Plain Override Solenoid Ends |
Spool Spring Arrangement Code | C |
Manual Override Option Code | None |
Temperature Range [Min] | -40 °F |
Mechanical Options Code | None |
Performance | High Performance |
Pilot/Drain | Internal Pilot/Internal Drain |
No. of Stages | Two Stage |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Electrical Options | None |
Solenoid Energization Code | None |
Gauge Ports Code | None |
Port T Pressure Rating | 5000 psi |
Coil Rating Code | B |
Pilot Valve Type | CETOP 3, High Performance |
Model No. | DG5V-8-H-6C-2-T-M-FW-B-10 |
Rated Flow [Max] | 175 gal/min |
Spool Control Modification Code | 2 |
Solenoid | Double |
Leakage | High Performance |
Temperature Range [Max] | 230 °F |
Tank Port Rating | 5000 |
Gauge Port | SAE-4 |
Port Restrictor Plug Code | None |
Spool Code | 6 |
Pressure Port Check Valve Code | None |
Pilot Drain Code | T |
Reducer Module Code | None |
Pressure Port Check Valve Pressure | N/A |
Surge Suppressor/Damper Code | None |
Actuator Type | Solenoid |
Surge Suppressor/Damper | None |
Pilot Pressure Code | None |
Operation | Pilot Operated |
Function | 3-Position Spring Centered |
Pressure [Max] | 5000 psi |
Pilot Valve Type Code | H |
Manual Override | Plain Override |
Housing Code | W |
Coil Type Code | F |
Electrical Connection | No Connector |
Actuation Identification | Solenoid A, Solenoid B |
Reducer Module | No |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Indicator Lights | No |
Design No. | 10 |
Compatible Fluids | Petroleum Oil |
Center Position | P Blocked, A & B to T |
Fluid Cleanliness | 19/17/14 micron |
Mechanical Options | Adjust Pilot Chokes on Both Ends |
Body Material | Ductile Iron |
Response Type Code | None |
Crossover | P Blocked, A or B to T |
Response Type | Standard Response |
Electrical Connector Code | None |
EN Code | None |
Seal Material | Buna-N |
Spool Indicator Switch Code | None |
NFPA Size | D08 |
Mounting | Subplate/Manifold Mount |
Solenoid Indicator Lights Code | None |
Electrical Options Code | None |
Port Restrictor Plugs | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Weight | 35.0 LB |