- Solenoid Actuated Valve
- Solenoid Operated Operation
- D10 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
applications
- Used to control large flows, to 1,100 l/min (290 US gpm)
features
- Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
- Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
- Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
- High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Temperature Range [Max] | 150.8 °F |
Valve Type | Standard-Duty |
Gauge Ports Code | None |
Response Type | Standard Response |
Electrical Connection | No Connector |
Actuation Identification | Solenoid A, Solenoid B |
Electrical Options | None |
Port Restrictor Plug Code | None |
Mechanical Options | None |
Electrical Options Code | None |
Solenoid Energization Code | None |
Pilot Pressure [Max] | 3000 psi |
Pilot Pressure Code | None |
Response Type Code | None |
Manual Override Option Code | None |
Pilot/Drain | Internal Drain |
Rated Flow [Max] | 175 gal/min |
Reducer Module | N/A |
EN Code | EN503 |
Surge Suppressor/Damper Code | None |
AC/DC | AC |
Overrides | None |
Temperature Range [Min] | -0.4 °F |
Spool Spring Arrangement Code | C |
Surge Suppressor/Damper | None |
Pressure Port Check Valve Code | None |
Coil Type Code | None |
Indicator Lights | Yes |
Seal Material | Buna-N |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
NFPA Size | D10 |
Function | 3-Position Spring Centered |
Body Material | Ductile Iron |
Fluid Cleanliness | 19/17/14 micron |
Operation | Solenoid Operated |
Model No. | DG5V-10-W-3C-T-M-L-B-10-EN503 |
Port T Pressure Rating | 3000 psi |
Actuator Type | Solenoid |
Crossover | All Ports Blocked, or P & B Blocked, A to T |
Pilot Valve Type Code | W |
Assembly Code | None |
Solenoid | Double |
No. of Stages | Two Stage |
Spool Code | 3 |
Pilot Valve Type | CETOP 5, Wet Armature |
Pilot Drain Code | T |
Reducer Module Code | None |
Coil Rating Code | B |
Coil Type | No Coil |
Port Restrictor Plugs | None |
Leakage | Standard Performance |
Mounting | Subplate/Manifold Mount |
Center Position | P & B Blocked, A to T |
Housing Code | None |
Solenoid Indicator Lights Code | L |
Electrical Connector Code | None |
Gauge Port | SAE-4 |
Pressure [Max] | 5000 psi |
Spool Control Modification Code | None |
Pressure Port Check Valve Pressure | N/A |
Design No. | 10 |
Compatible Fluids | Petroleum Oil |
Tank Port Rating | 3000 |
Manual Override | Plain Override |
Weight | 100.0 LB |