Skip to content Skip to navigation menu
Vickers02-360418

02-360418

Vickers D08 Solenoid Valve
Item #101906625
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-360418
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Design No. 10
Actuator Type Solenoid
Pilot Drain Code None
Spool Spring Arrangement Code C
Solenoid Energization Code V
Performance High Performance
Manual Override Plain Override
Port T Pressure Rating 5000 psi
Coil Type ISO 4400 (Din 43650) Connector
Surge Suppressor/Damper Code None
Indicator Lights No
Pilot Pressure Code None
Electrical Options Code None
Manual Override Option Code None
Body Material Gray Iron
Mounting Subplate/Manifold Mount
Mechanical Options Code None
Electrical Options None
Rated Flow [Max] 175 gal/min
Surge Suppressor/Damper None
EN Code None
Electrical Connector Code None
Spool Indicator Switch Code None
Overrides Plain Override Solenoid Ends
NFPA Size D08
AC/DC AC
Pressure [Max] 5000 psi
Leakage Standard Performance
No. of Stages Two Stage
Pressure Port Check Valve Code None
Operation Pilot Operated
Gauge Port SAE-4
Crossover All Ports Open, Restricted
Coil Rating Code B
Valve Type Standard-Duty
Center Position P to T, A & B Blocked
Pilot Valve Type Code H
Function 3-Position Spring Centered
Gauge Ports Code None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Coil Type Code U
Model No. DG5V-8-H-8C-VM-U-B-10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Seal Material Buna-N
Tank Port Rating 5000
Pilot/Drain External Pilot/Internal Drain
Port Restrictor Plug Code None
Spool Code 8
Housing Code None
Reducer Module Code None
Solenoid Double
Mechanical Options None
Pilot Valve Type CETOP 3, High Performance
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Response Type Code None
Port Restrictor Plugs None
Reducer Module No
Solenoid Indicator Lights Code None
Compatible Fluids Petroleum Oil
Spool Control Modification Code None
Pressure Port Check Valve Pressure N/A
Electrical Connection No Connector
Weight 35.0 LB