- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Response Type | Standard Response |
Port T Pressure Rating | 5000 psi |
Response Type Code | None |
Electrical Options | None |
Pilot Drain Code | None |
NFPA Size | D08 |
Performance | Standard Performance |
Pressure Port Check Valve Pressure | 5 psi |
Valve Type | Standard-Duty |
Housing Code | W |
Reducer Module | No |
Design No. | 10 |
Pilot Pressure Code | None |
Function | 3-Position Spring Centered |
Tank Port Rating | 5000 |
Actuator Type | Solenoid |
Spool Indicator Switch Code | None |
Temperature Range [Max] | 230 °F |
Surge Suppressor/Damper Code | None |
Pressure Port Check Valve Code | K |
Actuation Identification | Solenoid A, Solenoid B |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Solenoid Energization Code | None |
Mechanical Options Code | None |
Coil Rating Code | B |
Center Position | All Ports Blocked |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Mounting | Subplate/Manifold Mount |
Solenoid | Double |
Pilot Valve Type Code | S |
Crossover | All Ports Blocked |
Gauge Port | SAE-4 |
Spool Control Modification Code | None |
AC/DC | AC |
Operation | Pilot Operated |
Overrides | Plain Override Solenoid Ends |
Spool Code | 2 |
Leakage | Standard Performance |
Manual Override | Plain Override |
Spool Spring Arrangement Code | C |
Fluid Cleanliness | 19/17/14 micron |
Solenoid Indicator Lights Code | L |
Pilot Valve Type | CETOP 3, Standard Performance |
EN Code | None |
Surge Suppressor/Damper | None |
No. of Stages | Two Stage |
Manual Override Option Code | None |
Compatible Fluids | Petroleum Oil |
Pilot/Drain | Internal Pilot/External Drain |
Mechanical Options | None |
Port Restrictor Plugs | None |
Gauge Ports Code | None |
Reducer Module Code | None |
Rated Flow [Max] | 175 gal/min |
Port Restrictor Plug Code | None |
Pressure [Max] | 5000 psi |
Model No. | DG5V-8-S-2C-K-M-FTWL-B-10 |
Coil Type Code | F |
Electrical Connector Code | T |
Body Material | Ductile Iron |
Seal Material | Buna-N |
Electrical Connection | Wired Terminal Block |
Temperature Range [Min] | -40 °F |
Indicator Lights | Yes |
Electrical Options Code | None |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Weight | 35.0 LB |