- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Port Restrictor Plug Code | None |
Spool Code | 6 |
Model No. | DG5V-8-S-6C-K-M-FTWL-B-10 |
Body Material | Ductile Iron |
Center Position | P Blocked, A & B to T |
Crossover | P Blocked, A or B to T |
Valve Type | Standard-Duty |
Pilot/Drain | Internal Pilot/External Drain |
Function | 3-Position Spring Centered |
Leakage | Standard Performance |
Gauge Ports Code | None |
Pressure [Max] | 5000 psi |
Port Restrictor Plugs | None |
Solenoid | Double |
Mounting | Subplate/Manifold Mount |
Operation | Pilot Operated |
Performance | Standard Performance |
Reducer Module Code | None |
Electrical Connection | Wired Terminal Block |
Spool Indicator Switch Code | None |
Response Type Code | None |
Surge Suppressor/Damper Code | None |
Design No. | 10 |
No. of Stages | Two Stage |
Pilot Valve Type | CETOP 3, Standard Performance |
Reducer Module | No |
Pilot Drain Code | None |
Electrical Options Code | None |
NFPA Size | D08 |
Pilot Pressure Code | None |
Tank Port Rating | 5000 |
Mechanical Options Code | None |
Coil Type Code | F |
AC/DC | AC |
Solenoid Energization Code | None |
Spool Spring Arrangement Code | C |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Electrical Connector Code | T |
Pressure Port Check Valve Pressure | 5 psi |
Mechanical Options | None |
Compatible Fluids | Petroleum Oil |
Manual Override Option Code | None |
Pilot Valve Type Code | S |
Fluid Cleanliness | 19/17/14 micron |
Spool Control Modification Code | None |
Surge Suppressor/Damper | None |
Response Type | Standard Response |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Actuator Type | Solenoid |
Rated Flow [Max] | 175 gal/min |
Seal Material | Buna-N |
Gauge Port | SAE-4 |
Electrical Options | None |
Temperature Range [Max] | 230 °F |
Overrides | Plain Override Solenoid Ends |
EN Code | None |
Indicator Lights | Yes |
Pressure Port Check Valve Code | K |
Coil Rating Code | B |
Port T Pressure Rating | 5000 psi |
Temperature Range [Min] | -40 °F |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Solenoid Indicator Lights Code | L |
Manual Override | Plain Override |
Actuation Identification | Solenoid A, Solenoid B |
Housing Code | W |
Weight | 35.0 LB |