- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Spool Indicator Switch Code | None |
Gauge Ports Code | None |
Electrical Connector Code | None |
Fluid Cleanliness | 19/17/14 micron |
Surge Suppressor/Damper Code | None |
Port Restrictor Plugs | None |
Electrical Connection | No Connector |
Leakage | High Performance |
Performance | High Performance |
Pressure Port Check Valve Pressure | N/A |
Gauge Port | SAE-4 |
Pilot Valve Type Code | H |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Response Type Code | None |
AC/DC | AC |
Reducer Module | No |
Compatible Fluids | Petroleum Oil |
Body Material | Ductile Iron |
Mechanical Options | None |
Coil Type | ISO 4400 (Din 43650) Connector |
Operation | Pilot Operated |
Design No. | 10 |
Coil Rating Code | B |
Solenoid | Double |
EN Code | None |
Electrical Options Code | None |
Spool Spring Arrangement Code | C |
Reducer Module Code | None |
Function | 3-Position Spring Centered |
Housing Code | None |
Pressure Port Check Valve Code | None |
Crossover | All Ports Open, Restricted |
Tank Port Rating | 5000 |
Response Type | Standard Response |
Pilot/Drain | External Pilot/Internal Drain |
Port Restrictor Plug Code | None |
Rated Flow [Max] | 175 gal/min |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Center Position | P to T, A & B Blocked |
Spool Code | 8 |
Spool Control Modification Code | None |
Indicator Lights | No |
Pilot Pressure Code | E |
Coil Type Code | U |
Electrical Options | None |
Manual Override Option Code | None |
Surge Suppressor/Damper | None |
Manual Override | Plain Override |
Model No. | DG5V-8-H-8C-E-T-VM-U-B-10 |
Solenoid Energization Code | V |
Actuation Identification | Solenoid A, Solenoid B |
Overrides | Plain Override Solenoid Ends |
Temperature Range [Min] | -40 °F |
Mounting | Subplate/Manifold Mount |
NFPA Size | D08 |
Temperature Range [Max] | 230 °F |
Pressure [Max] | 5000 psi |
Pilot Valve Type | CETOP 3, High Performance |
Solenoid Indicator Lights Code | None |
Pilot Drain Code | T |
No. of Stages | Two Stage |
Seal Material | Buna-N |
Actuator Type | Solenoid |
Mechanical Options Code | None |
Valve Type | Standard-Duty |
Port T Pressure Rating | 5000 psi |
Weight | 35.0 LB |