- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pressure Port Check Valve Code | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Rated Flow [Max] | 175 gal/min |
Body Material | Ductile Iron |
Design No. | 10 |
Electrical Connection | Five Pin Connector |
Leakage | High Performance |
Fluid Cleanliness | 19/17/14 micron |
Model No. | DG5V-8-H-2C-T-M-FPA5WL-B-10 |
Overrides | Plain Override Solenoid Ends |
Performance | High Performance |
Pressure [Max] | 5000 psi |
AC/DC | AC |
Crossover | All Ports Blocked |
Electrical Options Code | None |
EN Code | None |
Port Restrictor Plug Code | None |
Pilot Valve Type | CETOP 3, High Performance |
Surge Suppressor/Damper Code | None |
Gauge Port | SAE-4 |
Tank Port Rating | 5000 |
Pilot Valve Type Code | H |
Center Position | All Ports Blocked |
Compatible Fluids | Petroleum Oil |
Spool Indicator Switch Code | None |
Spool Spring Arrangement Code | C |
Spool Control Modification Code | None |
Valve Type | Standard-Duty |
Electrical Options | None |
No. of Stages | Two Stage |
Mounting | Subplate/Manifold Mount |
Solenoid Indicator Lights Code | L |
Mechanical Options Code | None |
NFPA Size | D08 |
Response Type Code | None |
Solenoid | Double |
Temperature Range [Min] | -40 °F |
Pilot Drain Code | T |
Function | 3-Position Spring Centered |
Seal Material | Buna-N |
Mechanical Options | None |
Actuation Identification | Solenoid A, Solenoid B |
Pilot Pressure Code | None |
Response Type | Standard Response |
Reducer Module Code | None |
Spool Code | 2 |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Surge Suppressor/Damper | None |
Gauge Ports Code | None |
Reducer Module | No |
Housing Code | W |
Coil Rating Code | B |
Operation | Pilot Operated |
Coil Type Code | F |
Indicator Lights | Yes |
Actuator Type | Solenoid |
Solenoid Energization Code | None |
Manual Override Option Code | None |
Manual Override | Plain Override |
Pilot/Drain | External Pilot/Internal Drain |
Pressure Port Check Valve Pressure | N/A |
Electrical Connector Code | PA5 |
Port Restrictor Plugs | None |
Temperature Range [Max] | 230 °F |
Port T Pressure Rating | 5000 psi |
Weight | 35.0 LB |