- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pilot Pressure Code | None |
Coil Rating Code | B |
Pressure [Max] | 5000 psi |
Mechanical Options | Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends |
Reducer Module | N/A |
Spool Spring Arrangement Code | C |
Actuator Type | Solenoid |
Electrical Connector Code | None |
Operation | Pilot Operated |
Rated Flow [Max] | 185 gal/min |
Spool Indicator Switch Code | None |
Function | 3-Position Spring Centered |
Indicator Lights | No |
Pilot Drain Code | T |
Electrical Options | None |
Housing Code | W |
AC/DC | AC |
Pilot Valve Type | CETOP 3, High Performance |
Manual Override | Plain Override |
Gauge Ports Code | None |
Center Position | P Blocked, A & B to T |
Electrical Connection | No Connector |
Pressure Port Check Valve Pressure | N/A |
Coil Type Code | F |
Spool Control Modification Code | 3 |
Seal Material | Buna-N |
Valve Type | Standard-Duty |
Reducer Module Code | None |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Gauge Port | SAE-4 |
Model No. | DG5V-8-H-6C-3-T-M-FW-B-10 |
Mechanical Options Code | None |
Solenoid Indicator Lights Code | None |
Surge Suppressor/Damper Code | None |
Surge Suppressor/Damper | None |
Pressure Port Check Valve Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Electrical Options Code | None |
Manual Override Option Code | None |
Port Restrictor Plugs | None |
EN Code | None |
Crossover | P Blocked, A or B to T |
Pilot Valve Type Code | H |
Port T Pressure Rating | 5000 psi |
Response Type | Standard Response |
Pilot/Drain | External Pilot/Internal Drain |
Tank Port Rating | 5000 |
Response Type Code | None |
NFPA Size | D08 |
Solenoid | Double |
Port Restrictor Plug Code | None |
Overrides | Plain Override Solenoid Ends |
Design No. | 10 |
Solenoid Energization Code | None |
Spool Code | 6 |
Weight | 35.0 LB |