- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position, 4-Way, Spring Centered Function
description
- The DG5S8 are two-stage directional valves with an integrally-mounted DG4V3S pilot valve. These valves are used to control the direction of flow in hydraulic circuits.
compliances
- 0
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Spool Code | 2 |
Indicator Lights | Yes |
Surge Suppressor/Damper | None |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Compatible Fluids | Petroleum Oil |
Design No. | 10 |
Center Position | All Ports Blocked |
Function | 3-Position, 4-Way, Spring Centered |
Electrical Options | None |
Pilot Drain Code | T |
Performance | High Performance |
Surge Suppressor/Damper Code | None |
Mounting | Subplate/Manifold Mount |
Solenoid | Double |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Manual Override | Plain Override |
Response Type Code | None |
Port T Pressure Rating | 5000 psi |
Leakage | Standard Performance |
Port Restrictor Plug Code | None |
Mechanical Options Code | None |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Gauge Port | SAE-4 |
Pressure [Max] | 5000 psi |
Pilot Valve Type Code | H |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Pilot/Drain | External Pilot/Internal Drain |
No. of Stages | Two Stage |
Reducer Module | No |
Reducer Module Code | None |
Model No. | DG5V-8-H-2C-T-M-FTWL-B-10 |
Operation | Pilot Operated |
Coil Type Code | F |
Pilot Valve Type | CETOP 3, High Performance |
Pressure Port Check Valve Code | None |
Body Material | Gray Iron |
Housing Code | W |
Gauge Ports Code | None |
Port Restrictor Plugs | None |
Manual Override Option Code | None |
Mechanical Options | None |
Seal Material | Buna-N |
Rated Flow [Max] | 175 gal/min |
Crossover | All Ports Blocked |
Valve Type | Standard-Duty |
Actuator Type | Solenoid |
Pilot Pressure Code | None |
Spool Spring Arrangement Code | C |
NFPA Size | D08 |
Electrical Connection | Wired Terminal Block |
Fluid Cleanliness | 19/17/14 micron |
Spool Control Modification Code | None |
Response Type | Standard Response |
Overrides | Plain Override Solenoid Ends |
Spool Indicator Switch Code | None |
AC/DC | AC |
Coil Rating Code | B |
Solenoid Indicator Lights Code | L |
EN Code | None |
Electrical Options Code | None |
Solenoid Energization Code | None |
Electrical Connector Code | T |
Tank Port Rating | 5000 |
Pressure Port Check Valve Pressure | N/A |
Weight | 35.0 LB |