- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Design No. | 10 |
Coil Type Code | F |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Leakage | Standard Performance |
Compatible Fluids | Petroleum Oil |
Manual Override | Plain Override |
Body Material | Gray Iron |
Pilot/Drain | External Pilot/Internal Drain |
Surge Suppressor/Damper | None |
Pilot Valve Type Code | H |
Port Restrictor Plugs | None |
Solenoid Indicator Lights Code | None |
Pilot Valve Type | CETOP 3, High Performance |
Housing Code | W |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Mechanical Options Code | None |
Model No. | DG5V-8-H-8C-VM-FW-B-10 |
Gauge Ports Code | None |
Solenoid Energization Code | V |
Mechanical Options | None |
Gauge Port | SAE-4 |
Rated Flow [Max] | 175 gal/min |
Pressure Port Check Valve Pressure | N/A |
Coil Rating Code | B |
Tank Port Rating | 5000 |
Pressure Port Check Valve Code | None |
EN Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Crossover | All Ports Open, Restricted |
Seal Material | Buna-N |
Center Position | P to T, A & B Blocked |
Pilot Pressure Code | None |
Function | 3-Position Spring Centered |
Fluid Cleanliness | 19/17/14 micron |
Valve Type | Standard-Duty |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Electrical Connector Code | None |
Pressure [Max] | 5000 psi |
Electrical Connection | No Connector |
No. of Stages | Two Stage |
Performance | High Performance |
Spool Spring Arrangement Code | C |
Operation | Pilot Operated |
AC/DC | AC |
Electrical Options | None |
Response Type Code | None |
Reducer Module Code | None |
Spool Code | 8 |
Indicator Lights | No |
Response Type | Standard Response |
Surge Suppressor/Damper Code | None |
Port Restrictor Plug Code | None |
Spool Indicator Switch Code | None |
Mounting | Subplate/Manifold Mount |
NFPA Size | D08 |
Solenoid | Double |
Electrical Options Code | None |
Overrides | Plain Override Solenoid Ends |
Reducer Module | No |
Spool Control Modification Code | None |
Pilot Drain Code | None |
Manual Override Option Code | None |
Port T Pressure Rating | 5000 psi |
Actuator Type | Solenoid |
Weight | 35.0 LB |