- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Detented Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Mounting | Subplate/Manifold Mount |
Seal Material | Buna-N |
Port Restrictor Plug Code | None |
Pilot Valve Type | CETOP 3, Standard Performance |
Port Restrictor Plugs | None |
Gauge Port | SAE-4 |
Spool Spring Arrangement Code | N |
Mechanical Options Code | None |
Electrical Options Code | None |
Rated Flow [Max] | 175 gal/min |
Temperature Range [Min] | -40 °F |
AC/DC | AC |
Manual Override Option Code | None |
Spool Control Modification Code | 2 |
Actuator Type | Solenoid |
No. of Stages | Two Stage |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Design No. | 10 |
Body Material | Ductile Iron |
Compatible Fluids | Petroleum Oil |
Tank Port Rating | 5000 |
EN Code | None |
Valve Type | Standard-Duty |
Fluid Cleanliness | 19/17/14 micron |
Response Type | Standard Response |
Reducer Module Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Pilot Drain Code | None |
Pilot Pressure Code | None |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Pressure Port Check Valve Code | None |
Mechanical Options | Adjust Pilot Chokes on Both Ends |
Surge Suppressor/Damper Code | None |
Overrides | Plain Override Solenoid Ends |
Response Type Code | None |
Model No. | DG5V-8-S-6N-2-M-FTWL-B-10 |
Solenoid Indicator Lights Code | L |
Indicator Lights | Yes |
Electrical Options | None |
Manual Override | Plain Override |
Leakage | Standard Performance |
Operation | Pilot Operated |
Gauge Ports Code | None |
Pilot/Drain | Internal Pilot/External Drain |
Port T Pressure Rating | 5000 psi |
Solenoid | Double |
Center Position | P Blocked, A & B to T |
Electrical Connector Code | T |
NFPA Size | D08 |
Function | 3-Position Detented |
Coil Rating Code | B |
Coil Type Code | F |
Surge Suppressor/Damper | None |
Temperature Range [Max] | 230 °F |
Pressure [Max] | 5000 psi |
Pressure Port Check Valve Pressure | N/A |
Actuation Identification | Solenoid A, Solenoid B |
Reducer Module | No |
Spool Indicator Switch Code | None |
Housing Code | W |
Crossover | P Blocked, A or B to T |
Solenoid Energization Code | None |
Spool Code | 6 |
Electrical Connection | Wired Terminal Block |
Performance | Standard Performance |
Pilot Valve Type Code | S |
Weight | 35.0 LB |