- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
Rated Flow [Max] | 175 gal/min |
Overrides | Plain Override Solenoid Ends |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Electrical Connection | No Connector |
Function | 3-Position Spring Centered |
Indicator Lights | No |
AC/DC | AC |
Pilot Drain Code | None |
Coil Type Code | U |
Electrical Options | None |
Port Restrictor Plugs | None |
Spool Control Modification Code | None |
Center Position | P to T, A & B Blocked |
Response Type | Standard Response |
Electrical Connector Code | None |
Pilot Valve Type Code | S |
Solenoid Indicator Lights Code | None |
Manual Override | Plain Override |
Gauge Port | SAE-4 |
Solenoid | Double |
Pilot/Drain | Internal Pilot/External Drain |
Reducer Module | No |
Port T Pressure Rating | 5000 psi |
Surge Suppressor/Damper | None |
Port Restrictor Plug Code | None |
Fluid Cleanliness | 19/17/14 micron |
Solenoid Energization Code | V |
Electrical Options Code | None |
NFPA Size | D08 |
Leakage | Standard Performance |
Temperature Range [Max] | 230 °F |
Valve Type | Standard-Duty |
Crossover | All Ports Open, Restricted |
Tank Port Rating | 5000 |
Pilot Pressure Code | None |
Gauge Ports Code | None |
Response Type Code | None |
Manual Override Option Code | None |
No. of Stages | Two Stage |
Compatible Fluids | Petroleum Oil |
Housing Code | None |
Coil Rating Code | D |
Operation | Pilot Operated |
Actuator Type | Solenoid |
Mounting | Subplate/Manifold Mount |
Reducer Module Code | None |
Pilot Valve Type | CETOP 3, Standard Performance |
Pressure Port Check Valve Pressure | N/A |
Seal Material | Buna-N |
Spool Indicator Switch Code | None |
EN Code | None |
Performance | Standard Performance |
Spool Spring Arrangement Code | C |
Surge Suppressor/Damper Code | None |
Voltage & Frequency | 220/240 VAC - 50/60 Hz |
Mechanical Options Code | None |
Actuation Identification | Solenoid A, Solenoid B |
Temperature Range [Min] | -40 °F |
Coil Type | ISO 4400 (Din 43650) Connector |
Body Material | Ductile Iron |
Pressure Port Check Valve Code | None |
Design No. | 10 |
Spool Code | 8 |
Pressure [Max] | 5000 psi |
Model No. | DG5V-8-S-8C-VM-U-D-10 |
Mechanical Options | None |
Weight | 35.0 LB |