Vickers D08 Solenoid Valve
Item #102084135
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-329180
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Spool Code 6
Manual Override Plain Override
Mechanical Options None
Electrical Connection No Connector
Pilot/Drain External Pilot/Internal Drain
Temperature Range [Min] -40 °F
Coil Rating Code B
Spool Indicator Switch Code None
Mechanical Options Code None
Fluid Cleanliness 19/17/14 micron
Port T Pressure Rating 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Actuator Type Solenoid
Gauge Ports Code None
Center Position P Blocked, A & B to T
Temperature Range [Max] 230 °F
Pressure [Max] 5000 psi
Spool Control Modification Code None
Operation Pilot Operated
Overrides Plain Override Solenoid Ends
AC/DC AC
Voltage & Frequency 110/120 VAC - 50/60 Hz
Gauge Port SAE-4
Coil Type Code F
Port Restrictor Plug Code None
Manual Override Option Code None
Rated Flow [Max] 175 gal/min
Electrical Connector Code None
Valve Type Standard-Duty
Compatible Fluids Petroleum Oil
Port Restrictor Plugs None
Actuation Identification Solenoid A, Solenoid B
Design No. 10
EN Code None
Solenoid Indicator Lights Code None
Response Type Code None
Response Type Standard Response
Housing Code W
Electrical Options None
Pilot Pressure Code None
Pilot Valve Type CETOP 3, Standard Performance
NFPA Size D08
Tank Port Rating 5000
Pressure Port Check Valve Pressure N/A
Seal Material Buna-N
Function 3-Position Spring Centered
Solenoid Energization Code None
Leakage Standard Performance
Pilot Valve Type Code S
Reducer Module Code None
Indicator Lights No
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Reducer Module No
Crossover P Blocked, A or B to T
Pilot Drain Code T
Model No. DG5V-8-S-6C-T-M-FW-B-10
Electrical Options Code None
Surge Suppressor/Damper None
Spool Spring Arrangement Code C
Body Material Ductile Iron
Surge Suppressor/Damper Code None
Performance Standard Performance
Pressure Port Check Valve Code None
Mounting Subplate/Manifold Mount
Solenoid Double
No. of Stages Two Stage
Weight 35.0 LB