Skip to content Skip to navigation menu
Vickers02-329139

02-329139

Vickers D08 Solenoid Valve
Item #101978169
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-329139
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Solenoid Double
Port T Pressure Rating 5000 psi
Spool Spring Arrangement Code C
Spool Indicator Switch Code None
Manual Override Option Code None
Seal Material Buna-N
Port Restrictor Plugs None
Solenoid Indicator Lights Code None
Gauge Ports Code None
Gauge Port SAE-4
Function 3-Position Spring Centered
Surge Suppressor/Damper None
Spool Control Modification Code None
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
Electrical Connector Code None
Pressure Port Check Valve Code R
Operation Pilot Operated
Indicator Lights No
EN Code None
Tank Port Rating 5000
Design No. 10
Pilot Valve Type CETOP 3, Standard Performance
Reducer Module N/A
Electrical Connection No Connector
Spool Code 4
Pilot Valve Type Code S
Electrical Options Code None
Mechanical Options None
Overrides Plain Override Solenoid Ends
Electrical Options None
Coil Type Code F
Pilot Pressure Code None
Response Type Code None
Solenoid Energization Code V
Pilot/Drain External Pilot/Internal Drain
Pilot Drain Code None
Housing Code W
Crossover All Ports Blocked
Rated Flow [Max] 185 gal/min
Pressure Port Check Valve Pressure 50 psi
Model No. DG5V-8-S-4C-R-VM-FW-B-10
AC/DC AC
Surge Suppressor/Damper Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Center Position Tandem P to T
Coil Rating Code B
Valve Type Standard-Duty
Reducer Module Code None
Actuator Type Solenoid
Mechanical Options Code None
Manual Override Plain Override
NFPA Size D08
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Type Standard Response
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison