- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Gauge Ports Code | None |
Pilot Pressure Code | None |
Center Position | All Ports Blocked |
Operation | Pilot Operated |
Solenoid Indicator Lights Code | L |
Model No. | DG5V-8-S-2C-2-M-FTWL-B-10 |
Tank Port Rating | 5000 |
Pilot Valve Type | CETOP 3, Standard Performance |
Actuator Type | Solenoid |
Pressure Port Check Valve Pressure | N/A |
Body Material | Ductile Iron |
Performance | Standard Performance |
Mechanical Options | Adjust Pilot Chokes on Both Ends |
Valve Type | Standard-Duty |
Spool Indicator Switch Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Electrical Options Code | None |
Solenoid Energization Code | None |
AC/DC | AC |
Seal Material | Buna-N |
Leakage | Standard Performance |
Housing Code | W |
Overrides | Plain Override Solenoid Ends |
Pilot Drain Code | None |
Coil Type Code | F |
Electrical Connector Code | T |
NFPA Size | D08 |
Crossover | All Ports Blocked |
No. of Stages | Two Stage |
Surge Suppressor/Damper | None |
Pressure Port Check Valve Code | None |
Electrical Options | None |
Electrical Connection | Wired Terminal Block |
Pilot Valve Type Code | S |
Pilot/Drain | Internal Pilot/External Drain |
Response Type | Standard Response |
Reducer Module | No |
Compatible Fluids | Petroleum Oil |
Temperature Range [Max] | 230 °F |
Surge Suppressor/Damper Code | None |
Port Restrictor Plug Code | None |
Manual Override | Plain Override |
Spool Spring Arrangement Code | C |
Temperature Range [Min] | -40 °F |
Spool Control Modification Code | 2 |
EN Code | None |
Response Type Code | None |
Solenoid | Double |
Fluid Cleanliness | 19/17/14 micron |
Gauge Port | SAE-4 |
Manual Override Option Code | None |
Rated Flow [Max] | 175 gal/min |
Port Restrictor Plugs | None |
Function | 3-Position Spring Centered |
Actuation Identification | Solenoid A, Solenoid B |
Mounting | Subplate/Manifold Mount |
Design No. | 10 |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Pressure [Max] | 5000 psi |
Reducer Module Code | None |
Indicator Lights | Yes |
Spool Code | 2 |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Coil Rating Code | B |
Port T Pressure Rating | 5000 psi |
Mechanical Options Code | None |
Weight | 35.0 LB |