Skip to content Skip to navigation menu
Vickers02-329101

02-329101

Vickers D08 Solenoid Valve
Item #101979717
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers02-329101
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Options None
Center Position All Ports Blocked
Performance Standard Performance
Spool Control Modification Code None
Electrical Connector Code T
Housing Code W
Rated Flow [Max] 175 gal/min
Pressure Port Check Valve Pressure N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Manual Override Plain Override
Tank Port Rating 5000
Gauge Ports Code None
Operation Pilot Operated
Mechanical Options None
Pilot Drain Code T
Leakage Standard Performance
Spool Code 2
Body Material Ductile Iron
Fluid Cleanliness 19/17/14 micron
Solenoid Energization Code None
Compatible Fluids Petroleum Oil
Coil Rating Code B
Pressure [Max] 5000 psi
Solenoid Indicator Lights Code L
Pilot/Drain Internal Pilot/Internal Drain
Temperature Range [Max] 230 °F
Function 2-Position Spring Offset
Response Type Standard Response
Pilot Valve Type CETOP 3, Standard Performance
Port T Pressure Rating 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Gauge Port SAE-4
Surge Suppressor/Damper Code None
Pilot Pressure Code None
Seal Material Buna-N
Design No. 10
Overrides Plain Override Solenoid Ends
Coil Type Code F
Reducer Module No
Electrical Options Code None
Response Type Code None
AC/DC AC
EN Code None
Electrical Connection Wired Terminal Block
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper None
Indicator Lights Yes
Valve Type Standard-Duty
Reducer Module Code None
Pilot Valve Type Code S
Mechanical Options Code None
Actuator Type Solenoid
Crossover All Ports Blocked
NFPA Size D08
Spool Spring Arrangement Code A
Model No. DG5V-8-S-2A-T-M-FTWL-B-10
Spool Indicator Switch Code None
Solenoid Single
Port Restrictor Plugs None
Port Restrictor Plug Code None
Actuation Identification Solenoid B
Temperature Range [Min] -40 °F
No. of Stages Two Stage
Pressure Port Check Valve Code None
Manual Override Option Code None
Weight 35.0 LB