Vickers D03 Solenoid Valve

02-311556

Vickers D03 Solenoid Valve
Item #102088184
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Up to 21 gpm at 5,000 psi
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
Compatible Fluids Petroleum Oil
Solenoid Energization Code V
Fluid Cleanliness 19/17/14 micron
Solenoid Code H
Pilot Valve Type N/A
Mounting Subplate/Manifold Mount
Seal Material Buna-N
Voltage & Frequency 24 VDC
Surge Suppressor/Damper None
Response Type Standard Response
Model No. DG4V-3-8BL-VM-U-H7-61
Rated Flow [Max] 20 gal/min
Crossover All Ports Open, Restricted
EN Code None
Body Material Gray Iron
Electrical Options None
Housing Code None
Spool Code 8
No. of Stages Single Stage
Port Restrictor Plugs None
Spool Shift Timing N/A
Coil Rating Code H
NFPA Size D03
Electrical Connector Code None
Design No. 61
Operation Solenoid Operated
Solenoid Indicator Lights Code None
Temperature Range [Min] -4 °F
Function 2-Position Spring Offset, End To Center, Left Hand Build
Watt Rating 30 W
Surge Suppressor/Damper Code None
Valve Type High-Performance
Spool Indicator Switch Code None
Coil Type ISO 4400
Manual Override Plain Override
Tank Port Rating 3046
Solenoid Single
Performance High Performance
Reducer Module No
Mechanical Options None
Port T Code 7
Temperature Range [Max] 158 °F
Electrical Connection DIN 43650
Cycle Rate [Max] N/A
Pressure [Max] 5000 psi
Manual Override Option Code None
Spool Spring Arrangement Code B
Center Position P to T, A & B Blocked
Coil Type Code U
Pilot/Drain None
Leakage Standard Performance
AC/DC DC
Actuator Type Solenoid
Port T Pressure Rating 3000 psi
Response Time 28 to 45 ms
Overrides No Overrides
Port Restrictor Plug Code None
Actuation Identification Solenoid A
Function Code 8
Pressure Port Check Valve Pressure N/A
Indicator Lights No
Weight 5.0 LB