Vickers D03 Solenoid Valve

02-148442

Vickers D03 Solenoid Valve
Item #102085924
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
Pilot/Drain None
Indicator Lights No
Actuation Identification Solenoid A, Solenoid B
Seal Material Buna-N
Rated Flow [Max] 20 gal/min
Spool Code 2
Manual Override Plain Override
Pressure [Max] 5000 psi
Center Position All Ports Blocked
Response Time 15 to 23 ms
Tank Port Rating 3046
Port Restrictor Plug Code None
Electrical Connector Code None
Mechanical Options None
Pilot Valve Type N/A
Solenoid Indicator Lights Code None
Solenoid Double
Design No. 60
Valve Type High-Performance
Solenoid Energization Code None
AC/DC AC
Spool Spring Arrangement Code C
Spool Shift Timing N/A
Function Code 2
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Crossover All Ports Blocked
Cycle Rate [Max] N/A
Temperature Range [Max] 158 °F
Pressure Port Check Valve Pressure N/A
Coil Rating Code B
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper None
Leakage Standard Performance
Electrical Connection No Connector
Body Material Gray Iron
Port Restrictor Plugs None
EN Code EN21
Port T Code 6
Coil Type Code F
Model No. DG4V-3-2C-M-FW-B6-60-EN21
Housing Code W
Manual Override Option Code None
Response Type Standard Response
Function 3-Position Spring Centered
Overrides No Overrides
Electrical Options None
Solenoid Code B
Performance High Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Actuator Type Solenoid
Mounting Subplate/Manifold Mount
NFPA Size D03
Port T Pressure Rating 3000 psi
Temperature Range [Min] -4 °F
Surge Suppressor/Damper Code None
Spool Indicator Switch Code None
No. of Stages Single Stage
Operation Solenoid Operated
Weight 5.0 LB