Vickers D03 Solenoid Valve

02-110057

Vickers D03 Solenoid Valve
Item #101948365
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Options None
Reducer Module No
Port T Pressure Rating 1500 psi
Port T Code 5
Operation Solenoid Operated
Indicator Lights Yes
Rated Flow [Max] 10 gal/min
Solenoid Indicator Lights Code L
Compatible Fluids Petroleum Oil
Center Position All Ports Open
Seal Material Buna-N
No. of Stages Single Stage
Function 2-Position Spring Offset, End to Center
Temperature Range [Max] 158 °F
Spool Shift Timing N/A
Spool Code 0
Port Restrictor Plugs None
Crossover All Ports Open
Surge Suppressor/Damper None
Valve Type Standard-Duty
Temperature Range [Min] -4 °F
AC/DC AC
Solenoid Code B
Actuator Type Solenoid
Manual Override Plain Override
Pressure [Max] 5000 psi
Electrical Connection Wired Terminal Block
Overrides No Overrides
Performance Standard Performance
Port Restrictor Plug Code None
Solenoid Energization Code None
Pilot/Drain None
Pilot Valve Type N/A
Pressure Port Check Valve Pressure N/A
Electrical Connector Code T
Response Time 18 to 32 ms
Model No. DG4V 3S 0B M FTWL B5 60
Actuation Identification Solenoid B
Fluid Cleanliness 19/17/14 micron
Housing Code W
Response Type Standard Response
Surge Suppressor/Damper Code None
Cycle Rate [Max] N/A
Manual Override Option Code None
NFPA Size D03
Function Code 0
Coil Rating Code B
Tank Port Rating 1450
Leakage Standard Performance
Mechanical Options None
Solenoid Single
Spool Spring Arrangement Code B
Coil Type Code F
EN Code None
Design No. 60
Body Material Gray Iron
Mounting Subplate/Manifold Mount
Spool Indicator Switch Code None
Weight 5.0 LB