Vickers D03 Solenoid Valve

02-110057

Vickers D03 Solenoid Valve
Item #101948365
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Center Position All Ports Open
Mechanical Options None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
Body Material Gray Iron
Port T Pressure Rating 1500 psi
Indicator Lights Yes
Reducer Module No
Compatible Fluids Petroleum Oil
Rated Flow [Max] 10 gal/min
Coil Type Code F
NFPA Size D03
Actuation Identification Solenoid B
EN Code None
Surge Suppressor/Damper None
Valve Type Standard-Duty
Overrides No Overrides
Fluid Cleanliness 19/17/14 micron
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
Temperature Range [Min] -4 °F
Response Time 18 to 32 ms
Manual Override Option Code None
Design No. 60
Spool Code 0
Port T Code 5
Pilot Valve Type N/A
Temperature Range [Max] 158 °F
Solenoid Indicator Lights Code L
Voltage & Frequency 110/120 VAC - 50/60 Hz
Manual Override Plain Override
Function 2-Position Spring Offset, End to Center
Leakage Standard Performance
Solenoid Energization Code None
Function Code 0
Electrical Options None
Spool Indicator Switch Code None
Model No. DG4V 3S 0B M FTWL B5 60
Surge Suppressor/Damper Code None
Electrical Connector Code T
AC/DC AC
Spool Shift Timing N/A
Crossover All Ports Open
Pressure Port Check Valve Pressure N/A
Coil Rating Code B
Solenoid Code B
No. of Stages Single Stage
Electrical Connection Wired Terminal Block
Pilot/Drain None
Housing Code W
Mounting Subplate/Manifold Mount
Actuator Type Solenoid
Spool Spring Arrangement Code B
Operation Solenoid Operated
Cycle Rate [Max] N/A
Port Restrictor Plugs None
Solenoid Single
Performance Standard Performance
Response Type Standard Response
Tank Port Rating 1450
Weight 5.0 LB