Cryogenic service solenoid valves are designed to withstand the severe temperatures associated with controlling cryogenic fluids. Due to the sealing materials available for use at extremely low temperatures, slight leakage can be expected.
caution
Ratings are based on the use of synthetic lubricant which results in a cooler running unit, therefore thermal ratings are not necessary
Orifice Size
9/32 in
Coil Wattage Code
D
Seal Material Code
K
Body Material
Forged Brass
Current Design Code
A
Solenoid Enclosure Code
4
Connection Size
1/4
Coil Termination Code
C
Coil Insulation Code
F
Voltage Code
05
Flow Pattern Code
O
Body Material Code
2
Flow Pattern
Normally Open
Connection Type
NPT
Actuation Code
0
Connection Size Code
04
Valve Function
Cryogenic Fluids
Coil Termination
18 in Leads
Solenoid Enclosure
NEMA 4, 4X
Series Code
20
Voltage Rating
110 VAC, 50 Hz, 120 VAC, 60 Hz
Function
2-Way
Series
20
Function Code
2
Coil Current
AC
Seal Material
KEL F
Watt Rating
16 W
Orifice Size Code
18
Actuation
Direct Acting
Coil Insulation
Standard (Class 155)
Compatible Fluids
Cryogenic Fluids
Valve Type
Pressure Vessel w/Coil
Weight
0.75 LB