These three-way and four-way. valves are used to operate single-acting cylinders or to provide pilot signals to larger valves. A maintained mechanical force shifts the valve. Manual-return valves will remain in position until an opposite force is applied. Spring-return valves will return to normal position when force is removed from operator. These valves may be oriented in any position and are inline, foot, or panel mounted. Valves are prelubricated so airline lubrication is not necessary, but proper airline filtration and lubrication is recommended for longest service life.
features
Lubricated or nonlubricated service
Temperature range from 32 °F to 175 °F
Vacuum to 145 psig
Port Type
NPT
Return Type
Manual
Coil Style
No Coil
Series
Directair 2 Series
Spool Description
N/A
Stations
N/A
Width
0.620 in
Port Size
1/8
Voltage Rating
No Coil
Operation
Manual
Temperature Range [Max]
175 °F
Overrides
No Overrides
Height
1.310 in
Lights
No
Valve Type
4-Way, 2 Position
Operating Pressure Range
0 psi to 150 psi
Temperature Range [Min]
32 °F
Wiring Options
None
Valve Body Style
Body Ported
Cv Flow
0.2
Valve Duty
Standard Duty
Length
5.690 in
Installed Options
None
Actuator Type
Button, Push-Pull
Solenoid
N/A
Weight
0.666 LB
We're here for you
with Service Centers across the country - We have your back