These three-way and four-way. valves are used to operate single-acting cylinders or to provide pilot signals to larger valves. A maintained mechanical force shifts the valve. Manual-return valves will remain in position until an opposite force is applied. Spring-return valves will return to normal position when force is removed from operator. These valves may be oriented in any position and are inline, foot, or panel mounted. Valves are prelubricated so airline lubrication is not necessary, but proper airline filtration and lubrication is recommended for longest service life.
features
Lubricated or nonlubricated service
Temperature range from 32 °F to 175 °F
Vacuum to 145 psig
Series
Directair 2 Series
Voltage Rating
No Coil
Valve Type
4-Way, 2 Position
Port Size
1/8
Temperature Range [Min]
32 °F
Stations
N/A
Width
0.620 in
Overrides
No Overrides
Spool Description
N/A
Coil Style
No Coil
Operating Pressure Range
0 psi to 150 psi
Operation
Mechanical
Actuator Type
Roller
Return Type
Spring, w/ Foot Mount
Wiring Options
None
Cv Flow
0.2
Length
5.060 in
Lights
No
Temperature Range [Max]
175 °F
Valve Body Style
Body Ported
Roller Material
Delrin
Valve Duty
Standard Duty
Port Type
NPT
Installed Options
None
Solenoid
N/A
Height
1.310 in
Weight
0.666 LB
We're here for you
with Service Centers across the country - We have your back