Skip to content Skip to navigation menu
Vickers565779

565779

Vickers Pressure Control Cartridge Valve
Item #102028201
  • Pressure Control Valve
  • Pressure Relief Valve Type
  • RV5-10 Series
  • Cartridge Only Port Size
  • Cartridge Only Port Type
  • Pilot Operated Operation
+ Show More + Show Less
Vickers565779
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Pressure Control Valve
  • Pressure Relief Valve Type
  • RV5-10 Series
  • Cartridge Only Port Size
  • Cartridge Only Port Type

caution

  • Steel housings must be used for operating pressures above 3,000 psi
Pressure Setting 2792 psi
Temperature Range [Max] 248 °F
Recommend Filtration Level 18/16/13 microns
Seal Kit Buna 565803
Series RV5-10
Cage Seals Single Backup Ring
Leakage 114 cc/min
Installation Screw-in Cartridge
Housing Material Cartridge Only
Cavity C-10-2
Cracking Pressure [Min] 500 psi
No. of Valve Ports 2
Operating Pressure [Min] 508 psi
Flow [Max] 30 gal/min
Model No. RV5-10-K-0-50/
Seal Kit Viton 566086
Pressure [Max] 3452 psi
Port Size Cartridge Only
Manufacturer Part No. RV5-10-K-0-50/
Pilot Ratio 100:1
Operation Pilot Operated
No. of Housing Ports 2
Style Spool
Seal Material Buna-N
Port Type Cartridge Only
Adjustment Type Knob
Cracking Pressure [Max] 5000 psi
Temperature Range [Min] -40 °F
Valve Material Cartridge only
Operating Pressure [Max] 5076 psi
Type Pressure Relief Valve
Weight 0.48 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle