Vickers D03 Solenoid Valve

529763

Vickers D03 Solenoid Valve
Item #102040899
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Overrides No Overrides
Solenoid Single
Function 2-Position Spring Offset, End to End
Operation Solenoid Operated
Port Restrictor Plugs None
Electrical Options None
Coil Type Code U
Mechanical Options None
Coil Rating Code A
No. of Stages Single Stage
Spool Code 2
Body Material Gray Iron
Electrical Connection DIN 43650
Surge Suppressor/Damper Code None
Solenoid Code A
Port Restrictor Plug Code None
EN Code None
Response Type Standard Response
Leakage Standard Performance
Performance High Performance
Rated Flow [Max] 20 gal/min
Temperature Range [Max] 158 °F
Center Position All Ports Blocked
Crossover All Ports Blocked
Pilot/Drain None
Port T Code 6
Voltage & Frequency 110 VAC - 50 Hz
Fluid Cleanliness 19/17/14 micron
Spool Shift Timing N/A
Tank Port Rating 3046
Surge Suppressor/Damper None
Manual Override Plain Override
AC/DC AC
Temperature Range [Min] -4 °F
Seal Material Buna-N
Pilot Valve Type N/A
Port T Pressure Rating 3000 psi
Solenoid Energization Code None
Compatible Fluids Petroleum Oil
Design No. 60
Coil Type ISO 4400
Pressure Port Check Valve Pressure N/A
Valve Type High-Performance
Actuator Type Solenoid
Cycle Rate [Max] N/A
Housing Code None
Model No. DG4V 3 2A M U A6 60
Actuation Identification Solenoid B
Pressure [Max] 5000 psi
Reducer Module No
Solenoid Indicator Lights Code None
Indicator Lights No
Spool Indicator Switch Code None
Response Time 15 to 23 ms
Function Code 2
NFPA Size D03
Mounting Subplate/Manifold Mount
Electrical Connector Code None
Manual Override Option Code None
Spool Spring Arrangement Code A
Weight 3.22 LB