- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Coil Type Code | F |
Pressure [Max] | 5000 psi |
Spool Control Modification Code | None |
Electrical Options Code | None |
Reducer Module Code | None |
Manual Override Option Code | None |
EN Code | None |
Spool Code | 6 |
Function | 3-Position Spring Centered |
Response Type | Standard Response |
Surge Suppressor/Damper Code | None |
Port Restrictor Plugs | None |
Tank Port Rating | 5000 |
Mechanical Options Code | None |
Valve Type | Standard-Duty |
Reducer Module | N/A |
Operation | Pilot Operated |
Indicator Lights | Yes |
Solenoid Energization Code | None |
Mechanical Options | None |
Coil Rating Code | B |
Gauge Ports Code | None |
Actuator Type | Solenoid |
Gauge Port | SAE-4 |
Solenoid Indicator Lights Code | L |
Overrides | Plain Override Solenoid Ends |
Spool Spring Arrangement Code | C |
Response Type Code | None |
Electrical Connection | Wired Terminal Block |
Electrical Options | None |
Pressure Port Check Valve Code | None |
Port Restrictor Plug Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Model No. | DG5V-8-H-6C-E-M-FTWL-B-10 |
Pressure Port Check Valve Pressure | N/A |
Manual Override | Plain Override |
Crossover | P Blocked, A or B to T |
Pilot Pressure Code | E |
Pilot Drain Code | None |
Rated Flow [Max] | 185 gal/min |
Electrical Connector Code | T |
Pilot Valve Type | CETOP 3, High Performance |
Design No. | 10 |
Solenoid | Double |
NFPA Size | D08 |
Seal Material | Buna-N |
Pilot/Drain | External Pilot/Internal Drain |
AC/DC | AC |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Housing Code | W |
Pilot Valve Type Code | H |
Surge Suppressor/Damper | None |
Spool Indicator Switch Code | None |
Port T Pressure Rating | 5000 psi |
Center Position | P Blocked, A & B to T |
Weight | 35.0 LB |