- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Single Solenoid
- 2-Position Spring Offset Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Reducer Module Code | None |
Spool Spring Arrangement Code | A |
Electrical Options Code | None |
Indicator Lights | No |
Electrical Connection | No Connector |
Overrides | Plain Override Solenoid Ends |
Pressure Port Check Valve Pressure | N/A |
Solenoid | Single |
Gauge Port | SAE-4 |
Pilot Valve Type | CETOP 3, Standard Performance |
Gauge Ports Code | None |
Electrical Options | None |
Surge Suppressor/Damper | None |
Model No. | DG5V-8-S-0A-M-U-B-10 |
Coil Type | DIN 43650 |
Pressure [Max] | 5000 psi |
Spool Indicator Switch Code | None |
Response Type | Standard Response |
Tank Port Rating | 5000 |
Spool Control Modification Code | None |
Electrical Connector Code | None |
Seal Material | Buna-N |
Pressure Port Check Valve Code | None |
Operation | Pilot Operated |
Rated Flow [Max] | 185 gal/min |
Crossover | All Ports Open |
Coil Type Code | U |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Manual Override Option Code | None |
NFPA Size | D08 |
Solenoid Energization Code | None |
Surge Suppressor/Damper Code | None |
Pilot Valve Type Code | S |
EN Code | None |
Actuator Type | Solenoid |
Mechanical Options | None |
Manual Override | Plain Override |
Response Type Code | None |
Function | 2-Position Spring Offset |
Spool Code | 0 |
Valve Type | Standard-Duty |
Mechanical Options Code | None |
Design No. | 10 |
Port Restrictor Plug Code | None |
Coil Rating Code | B |
Pilot Pressure Code | None |
Reducer Module | N/A |
Center Position | All Ports Open |
Housing Code | None |
Port T Pressure Rating | 5000 psi |
Pilot Drain Code | None |
Port Restrictor Plugs | None |
Pilot/Drain | External Pilot/Internal Drain |
AC/DC | AC |
Solenoid Indicator Lights Code | None |
Weight | 35.0 LB |