- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Sudden, slam-type stalling should be avoided. Applications of this kind, which are beyond the expected normal performance of pneumatic power motors, will damage the power train due to the dynamic shock loads imposed.
Coil Rating Code | H |
Compatible Fluids | Petroleum Oil |
Design No. | 10 |
Rated Flow [Max] | 175 gal/min |
NFPA Size | D08 |
Mechanical Options Code | None |
Housing Code | None |
Crossover | P Blocked, A or B to T |
Pressure [Max] | 5000 psi |
Gauge Port | SAE-4 |
Electrical Options Code | None |
Electrical Connector Code | None |
Reducer Module | No |
Leakage | Standard Performance |
Spool Indicator Switch Code | None |
Tank Port Rating | 5000 |
Overrides | Plain Override Solenoid Ends |
Indicator Lights | No |
Mounting | Subplate/Manifold Mount |
Pilot/Drain | External Pilot/Internal Drain |
Spool Code | 6 |
Surge Suppressor/Damper | None |
Reducer Module Code | None |
Spool Spring Arrangement Code | C |
Response Type Code | None |
Spool Control Modification Code | None |
Voltage & Frequency | 24 VDC |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Pilot Pressure Code | None |
Mechanical Options | None |
Manual Override | Plain Override |
AC/DC | DC |
Port Restrictor Plugs | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Manual Override Option Code | None |
Fluid Cleanliness | 19/17/14 micron |
Electrical Connection | No Connector |
Center Position | P Blocked, A & B to T |
Electrical Options | None |
Body Material | Gray Iron |
Coil Type | ISO 4400 (Din 43650) Connector |
EN Code | None |
Model No. | DG5V-8-H-6C-T-M-U-H-10 |
Solenoid | Double |
Function | 3-Position Spring Centered |
Pilot Valve Type | CETOP 3, High Performance |
Actuator Type | Solenoid |
Response Type | Standard Response |
Pressure Port Check Valve Code | None |
Pilot Drain Code | T |
Coil Type Code | U |
Pressure Port Check Valve Pressure | N/A |
No. of Stages | Two Stage |
Port T Pressure Rating | 5000 psi |
Pilot Valve Type Code | H |
Seal Material | Buna-N |
Solenoid Indicator Lights Code | None |
Valve Type | Standard-Duty |
Performance | High Performance |
Surge Suppressor/Damper Code | None |
Gauge Ports Code | None |
Watt Rating | 30 W |
Port Restrictor Plug Code | None |
Solenoid Energization Code | None |
Operation | Pilot Operated |
Weight | 35.0 LB |