- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pressure [Max] | 5000 psi |
Pilot Valve Type Code | S |
Coil Rating Code | B |
Mechanical Options | None |
Port Restrictor Plugs | None |
Response Type | Standard Response |
Design No. | 10 |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Surge Suppressor/Damper | None |
Solenoid Indicator Lights Code | L |
Actuator Type | Solenoid |
Electrical Connection | Wired Terminal Block |
Manual Override | Plain Override |
Port T Pressure Rating | 5000 psi |
Pilot Valve Type | CETOP 3, Standard Performance |
Reducer Module Code | None |
Mechanical Options Code | None |
Gauge Ports Code | None |
Surge Suppressor/Damper Code | None |
Electrical Options Code | None |
Indicator Lights | Yes |
Pilot Pressure Code | None |
Spool Spring Arrangement Code | C |
Reducer Module | N/A |
Crossover | All Ports Blocked |
Valve Type | Standard-Duty |
Spool Code | 2 |
Gauge Port | SAE-4 |
Solenoid | Double |
Pilot/Drain | External Pilot/Internal Drain |
Tank Port Rating | 5000 |
EN Code | None |
Seal Material | Buna-N |
Electrical Connector Code | T |
Model No. | DG5V-8-S-2C-T-K-M-FTWL-B-10 |
Solenoid Energization Code | None |
Manual Override Option Code | None |
Electrical Options | None |
Response Type Code | None |
Housing Code | W |
NFPA Size | D08 |
Function | 3-Position Spring Centered |
Overrides | Plain Override Solenoid Ends |
Port Restrictor Plug Code | None |
Spool Indicator Switch Code | None |
AC/DC | AC |
Pressure Port Check Valve Pressure | 5 psi |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Pilot Drain Code | T |
Coil Type Code | F |
Operation | Pilot Operated |
Spool Control Modification Code | None |
Pressure Port Check Valve Code | K |
Center Position | All Ports Blocked |
Rated Flow [Max] | 185 gal/min |
Weight | 35.0 LB |