- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Design No. | 10 |
Response Type Code | None |
Crossover | All Ports Blocked |
Surge Suppressor/Damper Code | None |
Electrical Options | None |
Spool Indicator Switch Code | None |
Mounting | Subplate/Manifold Mount |
Solenoid | Double |
Coil Type Code | F |
Electrical Connection | Wired Terminal Block |
Pilot/Drain | External Pilot/External Drain |
Manual Override Option Code | None |
Performance | Standard Performance |
Compatible Fluids | Petroleum Oil |
Surge Suppressor/Damper | None |
Function | 3-Position Spring Centered |
Actuator Type | Solenoid |
Pilot Valve Type | CETOP 3, Standard Performance |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Pressure [Max] | 5000 psi |
Spool Control Modification Code | None |
Valve Type | Standard-Duty |
Overrides | Plain Override Solenoid Ends |
Port Restrictor Plugs | None |
Mechanical Options | None |
Response Type | Standard Response |
Seal Material | Buna-N |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Fluid Cleanliness | 19/17/14 micron |
Electrical Options Code | None |
Reducer Module Code | None |
Model No. | DG5V-8-S-4C-E-VM-FTWL-B-10 |
Pilot Drain Code | None |
No. of Stages | Two Stage |
Gauge Port | SAE-4 |
EN Code | None |
Spool Code | 4 |
Temperature Range [Min] | -40 °F |
Coil Rating Code | B |
Reducer Module | No |
Gauge Ports Code | None |
Rated Flow [Max] | 175 gal/min |
Pressure Port Check Valve Code | None |
Pilot Pressure Code | E |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Actuation Identification | Solenoid A, Solenoid B |
NFPA Size | D08 |
Solenoid Energization Code | V |
Leakage | Standard Performance |
Port Restrictor Plug Code | None |
Tank Port Rating | 5000 |
Spool Spring Arrangement Code | C |
Center Position | Tandem P to T |
Port T Pressure Rating | 5000 psi |
Electrical Connector Code | T |
AC/DC | AC |
Manual Override | Plain Override |
Indicator Lights | Yes |
Body Material | Ductile Iron |
Solenoid Indicator Lights Code | L |
Operation | Pilot Operated |
Mechanical Options Code | None |
Pilot Valve Type Code | S |
Temperature Range [Max] | 230 °F |
Pressure Port Check Valve Pressure | N/A |
Housing Code | W |
Weight | 35.0 LB |