- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Tank Port Rating | 5000 |
Electrical Options Code | None |
Housing Code | None |
AC/DC | AC |
Valve Type | Standard-Duty |
Spool Control Modification Code | 2 |
Pilot/Drain | Internal Pilot/Internal Drain |
Seal Material | Buna-N |
Function | 3-Position Spring Centered |
Reducer Module Code | None |
Design No. | 10 |
Port Restrictor Plugs | None |
Gauge Ports Code | None |
No. of Stages | Two Stage |
Coil Type Code | U |
Leakage | Standard Performance |
Fluid Cleanliness | 19/17/14 micron |
EN Code | None |
Pilot Valve Type | CETOP 3, Standard Performance |
Spool Spring Arrangement Code | C |
Body Material | Ductile Iron |
Pressure Port Check Valve Code | None |
Solenoid Indicator Lights Code | None |
Spool Indicator Switch Code | None |
Reducer Module | No |
Crossover | P Blocked, A or B to T |
Performance | Standard Performance |
Pilot Valve Type Code | S |
Pilot Drain Code | T |
NFPA Size | D08 |
Solenoid Energization Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Pressure [Max] | 5000 psi |
Mechanical Options | Adjust Pilot Chokes on Both Ends |
Manual Override | Plain Override |
Coil Rating Code | B |
Overrides | Plain Override Solenoid Ends |
Center Position | P Blocked, A & B to T |
Port T Pressure Rating | 5000 psi |
Indicator Lights | No |
Operation | Pilot Operated |
Electrical Connection | No Connector |
Coil Type | ISO 4400 (Din 43650) Connector |
Solenoid | Double |
Model No. | DG5V-8-S-6C-2-T-M-U-B-10 |
Electrical Options | None |
Surge Suppressor/Damper | None |
Pressure Port Check Valve Pressure | N/A |
Response Type | Standard Response |
Port Restrictor Plug Code | None |
Manual Override Option Code | None |
Pilot Pressure Code | None |
Rated Flow [Max] | 175 gal/min |
Mechanical Options Code | None |
Actuation Identification | Solenoid A, Solenoid B |
Surge Suppressor/Damper Code | None |
Temperature Range [Max] | 230 °F |
Temperature Range [Min] | -40 °F |
Electrical Connector Code | None |
Mounting | Subplate/Manifold Mount |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Gauge Port | SAE-4 |
Spool Code | 6 |
Compatible Fluids | Petroleum Oil |
Response Type Code | None |
Actuator Type | Solenoid |
Weight | 35.0 LB |