Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-333971

Vickers D03 Solenoid Valve
Item #102084194
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Overrides No Overrides
Temperature Range [Min] -4 °F
Port Restrictor Plug Code None
Valve Type High-Performance
Reducer Module No
Electrical Connector Code T
NFPA Size D03
Solenoid Indicator Lights Code L
Electrical Connection Wired Terminal Block
Spool Spring Arrangement Code C
Mounting Subplate/Manifold Mount
AC/DC DC
Surge Suppressor/Damper Code D7
Spool Shift Timing N/A
Coil Rating Code HL
Port Restrictor Plugs None
Body Material Gray Iron
Port T Code 7
Operation Solenoid Operated
Manual Override Option Code None
Housing Code W
Surge Suppressor/Damper Encapsulated Transzorb
Watt Rating 18 W
Design No. 60
Pressure [Max] 5000 psi
Port T Pressure Rating 3000 psi
Manual Override Plain Override
Function 3-Position Spring Centered
Voltage & Frequency 24 VDC
Response Type Standard Response
Solenoid Energization Code None
Function Code 6
Crossover P Blocked, A or B to T
Pilot Valve Type N/A
Compatible Fluids Petroleum Oil
Tank Port Rating 3046
Leakage Standard Performance
Solenoid Double
Solenoid Code HL
Seal Material Buna-N
Indicator Lights Yes
Cycle Rate [Max] N/A
Actuation Identification Solenoid A, Solenoid B
Model No. DG4V 3 6C M FTWL D7 HL7 60
Performance High Performance
Rated Flow [Max] 20 gal/min
Electrical Options None
Response Time 28 to 45 ms
Center Position P Blocked, A & B to T
Pressure Port Check Valve Pressure N/A
Temperature Range [Max] 158 °F
No. of Stages Single Stage
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Coil Type Code F
EN Code None
Spool Code 6
Pilot/Drain None
Spool Indicator Switch Code None
Actuator Type Solenoid
Mechanical Options None
Fluid Cleanliness 19/17/14 micron
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison