- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pilot Pressure Code | None |
Manual Override | Plain Override |
Electrical Options | None |
Temperature Range [Max] | 230 °F |
Indicator Lights | Yes |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
EN Code | None |
Actuation Identification | Solenoid A, Solenoid B |
Fluid Cleanliness | 19/17/14 micron |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Pressure Port Check Valve Pressure | N/A |
Housing Code | W |
Valve Type | Standard-Duty |
Pilot Drain Code | None |
Coil Rating Code | B |
Port T Pressure Rating | 5000 psi |
Manual Override Option Code | None |
Port Restrictor Plug Code | None |
Pilot Valve Type Code | S |
Pilot/Drain | External Pilot/Internal Drain |
Center Position | P Blocked, A & B to T |
Coil Type Code | F |
Seal Material | Buna-N |
Body Material | Ductile Iron |
Surge Suppressor/Damper | None |
Spool Spring Arrangement Code | C |
Performance | Standard Performance |
Pressure [Max] | 5000 psi |
Solenoid Energization Code | None |
Compatible Fluids | Petroleum Oil |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Electrical Connection | Wired Terminal Block |
No. of Stages | Two Stage |
Operation | Pilot Operated |
Actuator Type | Solenoid |
Surge Suppressor/Damper Code | None |
Temperature Range [Min] | -40 °F |
Pilot Valve Type | CETOP 3, Standard Performance |
Mounting | Subplate/Manifold Mount |
Mechanical Options | None |
Function | 3-Position Spring Centered |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Reducer Module | No |
Gauge Ports Code | None |
Rated Flow [Max] | 175 gal/min |
Model No. | DG5V-8-S-6C-M-FTWL-B-10 |
Pressure Port Check Valve Code | None |
Electrical Options Code | None |
Overrides | Plain Override Solenoid Ends |
Spool Indicator Switch Code | None |
Tank Port Rating | 5000 |
Mechanical Options Code | None |
Gauge Port | SAE-4 |
Leakage | Standard Performance |
AC/DC | AC |
Crossover | P Blocked, A or B to T |
Spool Control Modification Code | None |
Response Type | Standard Response |
Solenoid | Double |
NFPA Size | D08 |
Spool Code | 6 |
Response Type Code | None |
Port Restrictor Plugs | None |
Reducer Module Code | None |
Design No. | 10 |
Solenoid Indicator Lights Code | L |
Electrical Connector Code | T |
Weight | 35.0 LB |