Vickers02-329141

02-329141

Vickers D08 Solenoid Valve
Item #101979712
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-329141
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Crossover All Ports Blocked
Seal Material Buna-N
Surge Suppressor/Damper None
Valve Type Standard-Duty
Port T Pressure Rating 5000 psi
Spool Indicator Switch Code None
Coil Rating Code B
Pilot Valve Type CETOP 3, Standard Performance
AC/DC AC
Gauge Port SAE-4
Operation Pilot Operated
Pressure Port Check Valve Code None
Electrical Options None
Pressure [Max] 5000 psi
Manual Override Option Code None
Response Type Code None
Function 3-Position Spring Centered
Actuator Type Solenoid
Housing Code W
Port Restrictor Plug Code None
Model No. DG5V-8-S-4C-VM-FTWL-B-10
Reducer Module N/A
EN Code None
Pilot Pressure Code None
Pilot Drain Code None
Electrical Options Code None
Mechanical Options Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Solenoid Double
Surge Suppressor/Damper Code None
Electrical Connection Wired Terminal Block
Mechanical Options None
Design No. 10
Response Type Standard Response
Coil Type Code F
Pilot Valve Type Code S
Spool Control Modification Code None
Indicator Lights Yes
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Code 4
Solenoid Energization Code V
Overrides Plain Override Solenoid Ends
Port Restrictor Plugs None
NFPA Size D08
Pressure Port Check Valve Pressure N/A
Solenoid Indicator Lights Code L
Manual Override Plain Override
Pilot/Drain External Pilot/Internal Drain
Reducer Module Code None
Spool Spring Arrangement Code C
Gauge Ports Code None
Electrical Connector Code T
Tank Port Rating 5000
Rated Flow [Max] 185 gal/min
Center Position Tandem P to T
Weight 35.0 LB