Vickers02-329115

02-329115

Vickers D08 Solenoid Valve
Item #101978890
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-329115
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Mechanical Options None
Electrical Options Code None
Seal Material Buna-N
Model No. DG5V-8-S-2C-K-M-FW-B-10
Crossover All Ports Blocked
Pressure [Max] 5000 psi
Coil Type Code F
Function 3-Position Spring Centered
Housing Code W
Gauge Port SAE-4
Operation Pilot Operated
Pilot Valve Type Code S
Actuator Type Solenoid
Temperature Range [Max] 230 °F
Fluid Cleanliness 19/17/14 micron
Pilot Pressure Code None
Rated Flow [Max] 175 gal/min
AC/DC AC
Solenoid Energization Code None
Pilot Valve Type CETOP 3, Standard Performance
Leakage Standard Performance
Tank Port Rating 5000
Manual Override Plain Override
Performance Standard Performance
Surge Suppressor/Damper Code None
Design No. 10
Voltage & Frequency 110/120 VAC - 50/60 Hz
NFPA Size D08
Response Type Standard Response
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Electrical Options None
Port T Pressure Rating 5000 psi
Coil Rating Code B
Mechanical Options Code None
Pilot/Drain Internal Pilot/External Drain
Port Restrictor Plug Code None
Actuation Identification Solenoid A, Solenoid B
Spool Control Modification Code None
Indicator Lights No
Solenoid Double
Body Material Ductile Iron
Port Restrictor Plugs None
Pilot Drain Code None
Surge Suppressor/Damper None
Spool Code 2
Valve Type Standard-Duty
Electrical Connector Code None
Electrical Connection No Connector
Reducer Module Code None
Spool Indicator Switch Code None
No. of Stages Two Stage
Reducer Module No
EN Code None
Gauge Ports Code None
Manual Override Option Code None
Center Position All Ports Blocked
Solenoid Indicator Lights Code None
Temperature Range [Min] -40 °F
Mounting Subplate/Manifold Mount
Overrides Plain Override Solenoid Ends
Pressure Port Check Valve Code K
Response Type Code None
Compatible Fluids Petroleum Oil
Spool Spring Arrangement Code C
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure Port Check Valve Pressure 5 psi
Weight 35.0 LB