Item #102087859
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Voltage & Frequency 24 VDC
Temperature Range [Min] -4 °F
Function 2-Position Spring Offset, End To Center, Left Hand Build
Body Material Gray Iron
Spool Spring Arrangement Code B
Design No. 61
Rated Flow [Max] 20 gal/min
AC/DC DC
Indicator Lights No
Model No. DG4V-3-8BL-VM-FW-H7-61
Port Restrictor Plug Code None
Overrides No Overrides
Temperature Range [Max] 158 °F
Mounting Subplate/Manifold Mount
Performance High Performance
Port Restrictor Plugs None
Surge Suppressor/Damper None
Seal Material Buna-N
Mechanical Options None
Compatible Fluids Petroleum Oil
Fluid Cleanliness 19/17/14 micron
Pilot/Drain None
Manual Override Plain Override
Solenoid Code H
Valve Type High-Performance
Electrical Connector Code None
Center Position P to T, A & B Blocked
Pressure [Max] 5000 psi
Coil Rating Code H
Electrical Options None
Response Type Standard Response
Pressure Port Check Valve Pressure N/A
Response Time 28 to 45 ms
Function Code 8
Solenoid Single
No. of Stages Single Stage
Housing Code W
Reducer Module No
Cycle Rate [Max] N/A
Pilot Valve Type N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Operation Solenoid Operated
Leakage Standard Performance
Port T Code 7
Actuation Identification Solenoid A
Solenoid Energization Code V
Actuator Type Solenoid
Crossover All Ports Open, Restricted
Spool Code 8
NFPA Size D03
EN Code None
Watt Rating 30 W
Spool Shift Timing N/A
Manual Override Option Code None
Tank Port Rating 3046
Coil Type Code F
Solenoid Indicator Lights Code None
Port T Pressure Rating 3000 psi
Surge Suppressor/Damper Code None
Spool Indicator Switch Code None
Electrical Connection No Connector
Weight 5.0 LB