Skip to content Skip to navigation menu
Vickers02-305364

02-305364

Vickers D08 Solenoid Valve
Item #102089001
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers02-305364
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Aluminum housings can be used for pressures up to 3,000 psi
  • Steel housings must be used for operating pressures above 3,000 psi
Solenoid Single
Indicator Lights No
Reducer Module Code None
Electrical Options Code None
Surge Suppressor/Damper None
Housing Code W
Spool Indicator Switch Code None
Pressure Port Check Valve Code None
Tank Port Rating 5000
Electrical Options None
Manual Override Plain Override
Spool Code 0
Electrical Connector Code None
Rated Flow [Max] 185 gal/min
Manual Override Option Code None
Coil Type Code F
Actuator Type Solenoid
Surge Suppressor/Damper Code None
Seal Material Buna-N
Pressure Port Check Valve Pressure N/A
Overrides Plain Override Solenoid Ends
Gauge Ports Code None
AC/DC AC
Pilot Pressure Code E
NFPA Size D08
Port T Pressure Rating 5000 psi
Mechanical Options None
Valve Type Standard-Duty
Reducer Module N/A
Spool Control Modification Code None
Function 2-Position Spring Offset
Port Restrictor Plug Code None
Operation Pilot Operated
Pilot/Drain External Pilot/Internal Drain
EN Code None
Pilot Valve Type Code S
Port Restrictor Plugs None
Pilot Drain Code T
Pressure [Max] 5000 psi
Solenoid Indicator Lights Code None
Response Type Standard Response
Model No. DG5V-8-S-0A-E-T-M-FW-B-10
Coil Rating Code B
Design No. 10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options Code None
Solenoid Energization Code None
Spool Spring Arrangement Code A
Response Type Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection No Connector
Gauge Port SAE-4
Center Position All Ports Open
Pilot Valve Type CETOP 3, Standard Performance
Crossover All Ports Open
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison