Vickers D03 Solenoid Valve

02-300055

Vickers D03 Solenoid Valve
Item #102087478
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Seal Material Buna-N
No. of Stages Single Stage
Temperature Range [Max] 158 °F
Manual Override Plain Override
Performance High Performance
Design No. 60
Surge Suppressor/Damper None
Spool Shift Timing N/A
Indicator Lights No
Electrical Connector Code None
Tank Port Rating 3046
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Reducer Module No
Model No. DG4V-3-6N-M-FW-B6-60-EN21
Valve Type High-Performance
Mounting Subplate/Manifold Mount
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuator Type Solenoid
Port T Pressure Rating 3000 psi
Solenoid Double
Crossover P Blocked, A or B to T
Function 3-Position Detented
AC/DC AC
Body Material Gray Iron
Solenoid Energization Code None
Temperature Range [Min] -4 °F
Overrides No Overrides
Compatible Fluids Petroleum Oil
EN Code EN21
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
NFPA Size D03
Solenoid Indicator Lights Code None
Spool Code 6
Housing Code W
Pressure Port Check Valve Pressure N/A
Solenoid Code B
Pressure [Max] 5000 psi
Electrical Options None
Response Time 15 to 23 ms
Actuation Identification Solenoid A, Solenoid B
Pilot/Drain None
Coil Rating Code B
Spool Spring Arrangement Code N
Manual Override Option Code None
Surge Suppressor/Damper Code None
Fluid Cleanliness 19/17/14 micron
Pilot Valve Type N/A
Coil Type Code F
Function Code 6
Center Position P Blocked, A & B to T
Port T Code 6
Operation Solenoid Operated
Rated Flow [Max] 20 gal/min
Port Restrictor Plugs None
Response Type Standard Response
Electrical Connection No Connector
Leakage Standard Performance
Cycle Rate [Max] N/A
Mechanical Options None
Weight 5.0 LB